A new type arc suppression coil was proposed.
提出了一种新的消弧线圈。
The dynamic arc suppression coil compensation system is agile and effective.
动态消弧线圈补偿系统灵活高效。
This condition may be overcome in an isolated neutral system6 by means of an ARC suppression coil or Peterson Coil .
此情况在中性点绝缘系统中可通过消弧线圈或称彼得逊线圈加以克服。
Besides blowing out of arc principle of arc suppression coil and function principle of compensated electric net are explained.
此外还对消弧线圈熄弧原理和补偿电网的作用机理进行了说明。
The device's core is an arc suppression coil with changeable magnetizing current controlled by a microprocessor control system.
装置的核心部分是调励磁式消弧线圈和微机控制系统。
The new arc suppression coil control system consists of line selection device and automatic tuning device which communicate by CAN bus.
新型消弧线圈控制系统采用选线装置和调谐装置两套装置共同组成,两套装置通过CAN 总线进行通信。
With the integration of the method into the automatically regulated arc suppression coil compensation devices we can make feasible and…
结果表明该方法选线准确,耐过渡电阻能力强,并且易于实现与消弧线圈自动调谐装置的一体化协调运行。
The abnormal phenomenon of long time higher neutral voltage shift in a substation is analyzed, which is grounded through arc suppression coil.
针对变电所消弧线圈接地系统在正常运行情况下中性点位移电压长时间偏高现象,进行了分析。
The core structure of the arc suppression coil is improved to solve the nonlinearity of voltage with zero-excitation. The harm of ferro-resonance is thus reduced.
同时,通过改变消弧线圈铁芯结构,解决了在零励磁情况下电感的非线性问题,减少了铁磁谐振对电网造成的危害;
In coordination with the application of post-set arc suppression coil, a frequency scanning based modified method for detecting system capacitance to earth is proposed.
为配合随调式消弧线圈的使用,提出了一种扫频检测系统对地电容的改进型方法。
It is pointed out that the proper adjustment of arc suppression coil and coordination of system parameters may reduce the setting values and improve the running reliability.
通过计算及试验指出,合理调整消弧线圈与系统参数的配合,可以降低保护定值,提高运行可靠性。
Based on arc suppression coil self-loss conductance and line-to-ground conductance, the power grid-to-ground capacitive current and arc suppression coil tuning parameters is calculated.
同时在考虑消弧线圈自身损耗电导和线路对地电导的基础上,推导了电网对地电容电流和消弧线圈调谐参数的实时计算方法。
The paper introduces equipment of intelligent arc suppression coil grounded compensation. Itovercomes shortcoming in restricting harmonic over-voltage existed in old arc suppression coil.
国产智能型消弧限压接地补偿成套装置在限制谐振过电压方面,克服了老式调匝式消弧线圈存在的缺点。
The arc suppression coil with three phases and five columns can achieve automatic trace and compensation for ground fault capacitive current of power system by the method of rectifying i.
介绍了三相五柱式消弧线圈及其自动跟踪补偿原理,该消弧线圈在结构上突破了传统消弧线圈的模式,将传统的接地变压器和消弧线圈有机地结合成一个整体。
The cable outlets for 10kV distribution network system are added and the network is continuously expanded, the system principle of the netural point though arc suppression coil grounding is analyzed.
随着电缆在配电网中的大量应用,系统电容电流水平不断提高,准确便捷地测量配电网系统对地电容电流成为研究领域的热点。
At last, the characteristics of capacitor tuning arc-suppression reactor are summarized, which draws a conclusion that capacitor-tuning arc-suppression coil has a good application prospect.
最后总结了调容式自动消弧线圈的特点,得出调容式自动消弧线圈是一种比较有前景的补偿装置的结论。
A new structure of arc - suppression coil with magnetic bias and its control method is presented.
提出了一种新结构的偏磁式消弧线圈及其控制方法。
Based on the detailed analysis of the various automatic tuning principle of the arc-suppression coil, a tuning method of the magnetic bias ASC is acquired.
在对消弧线圈的各种自动调谐原理系统分析的基础上,确定了适用于偏磁式消弧线圈的调谐方法。
The DSP realizes functions of sampling, PI regulation, communication and so on to digitally control the excitation current of arc-suppression coil with magnetic bias.
DSP主要完成采样、PI调节和通信等,实现偏磁式消弧线圈励磁电流的数字控制。
Based on it's working principle, we determine the arc-suppression coil with magnetic bias methods.
依据偏磁式消弧线圈的工作原理,确定了偏磁式消弧线圈的控制方法。
Precisely measuring and tracing is a precondition and basis of arc-suppression coil with automatic tuning accurately compensating system capacitive current and efficiently quenching ground arc.
精确的测量和跟踪是自动调谐式消弧线圈精确地补偿系统电容电流、有效地熄灭接地点电弧的前提和基础。
Generator neutral ground methods include non-ground, low impedance ground, high impedance ground and arc-suppression coil ground.
发电机中性点运行方式有中性点不接地、小阻抗接地、高阻抗接地、消弧线圈接地。
The principle of arc-suppression coil with three phases and five columns , and theory of power frequency extinguishing arcing were introduced.
介绍了三相五柱式消弧线圈的工作原理,单相电弧接地过电压的工频熄弧理论。
Based on the detailed analysis of the various automatic tuning principle of the arc-suppression coil (ASC), a tuning method of the magnetic bias ASC is acquired.
在对消弧线圈的各种自动调谐原理系统分析的基础上,确定了适用于偏磁式消弧线圈的调谐方法。依据偏磁式消弧线圈的工作原理,确定了偏磁式消弧线圈的控制方法。
The precise tuning of the arc-suppression coil can be realized on the basis of the precise value of the tuning-off degree and the capacitive current.
在准确测量脱谐度和电容电流的基础上,可实现对消弧线圈的精确调谐。
An incorporate device of automatic arc-suppression coil and grounding fault line selection based on modularity structure was developed to improve its reliability and flexibility.
为提高可靠性和使用的灵活性,开发了一种模块化结构的自动消弧线圈及接地选线成套装置,给出了二者的硬件设计和接地故障子程序设计。
Non-ground neutral system and arc-suppression-coil-ground neutral system are called non-direct ground neutral system that is widely used in power distribution system.
中性点不接地系统和中性点经消弧线圈接地系统统称为中性点不直接接地系统,广泛应用于铁路配电系统中。
Non-ground neutral system and arc-suppression-coil-ground neutral system are called non-direct ground neutral system that is widely used in power distribution system.
中性点不接地系统和中性点经消弧线圈接地系统统称为中性点不直接接地系统,广泛应用于铁路配电系统中。
应用推荐