The article introduces the design of level bearing performance experiment model for cable pylon anchorage zone of Yellow River No.
该文介绍了济南黄河三桥索塔锚固区水平受力性能试验模型的设计;通过有限元分析,对试验模型和实际结构的受力进行了比较。
Anchorage zone of pylon, which is a key part of cable-stayed bridge, can pass local concentrated cable force to the tower column safely and uniformly.
索塔·拉索锚固区是斜拉桥中的关键部位,其作用是将拉索的局部集中力安全,均匀地传递到塔柱。
Whether the connection between steel plate and concrete pylon wall was reliable related to the safety of the whole anchorage zone of pylon.
钢板和混凝土塔壁之间的连接的是否可靠,关系到整个索塔锚固区的安全。
The anchorage zone of the pylon is a key part for cable-stayed Bridges, where the concentrated force of cable will be transferred to the pylon safely and uniformly.
索塔·拉索锚固区是斜拉桥的关键部位,拉索的集中力将通过这一部位安全、均匀地传递到塔柱中。
This thesis sets out to make brief introduction of the full-scale model test and test result of the anchorage zone of the pylon.
本文简要介绍了索塔锚固区节段足尺模型试验及试验结果。
The model anti-crack safety coefficient are bigger than 1.65, the anchorage zone of the pylon are safely and reliable.
模型的抗裂安全系数大于1.65,索塔结构锚固区设计安全可靠。
The model anti-crack safety coefficient are bigger than 1.65, the anchorage zone of the pylon are safely and reliable.
模型的抗裂安全系数大于1.65,索塔结构锚固区设计安全可靠。