For energized icing, icing state, ice density and flashover voltage are affected.
带电覆冰对绝缘子的覆冰状况、覆冰密度和闪络电压均有影响。
When air humidity is 95%flashover voltage triggered by laser only increase 5%than that when air humidity is 40%.
空气湿度在95%相对湿度下较40%相对湿度下,相同激光能量触发的放电电压提高5%。
The current and voltage response of surge discharge circuit to impulse flashover voltage test system is analyzed.
对电力电缆故障冲击高压闪络测试(简称冲闪测试)系统的放电响应进行了研究。
The flashover voltage of iced insulators of transmission lines is affected by the electrical characteristic of ice.
冰的电气特性影响输电线路覆冰绝缘子闪络电压。
A mathematical model is presented according to the mechanism of DC pollution flashover for computing DC pollution flashover voltage.
在现有污闪机理的基础上,提出一种能反映直流污闪基本特点,并计算绝缘子直流污闪电压的数学模型。
The flashover voltage of polluted composite insulators is decreased with increase of SDD and the fog conductivity in acid fog and salt fog.
污秽合成绝缘子在酸雾、盐雾中闪络电压随污秽程度的增大而降低,随雾水电导率的增加而降低。
The discharge at the top of icicle is one of the main factors influencing flashover voltage when the air gap amid the sheds of ice-covered insulators is not bridged.
覆冰绝缘子伞裙间隙未桥接时,冰凌尖端的放电是影响绝缘子闪络电压的主要因素之一。
The effect of charges remaining on a dielectric plate upon the 50% impulse surface flashover voltage U_ (50) in the non-uniform field (rod-plane gap) is investigated.
针对不均匀电场(棒-板间隙)中绝缘板上残余电荷对50%冲击闪络电压u _(50)的影响做了一些试验研究。
Meanwhile, the factors which affect the flashover voltage of ceramic insulators were analyzed, the methods for improving the hold-off voltage were recommended from the in.
接触网覆冰不仅影响接触线的弛度、支柱的容量,在一定程度上还影响着接触网绝缘子的闪络电压。
The flashover performance of ice-covered XZP-210 insulator strings was investigated and the effects of the string length and arrangement on the icing flashover voltage were analyzed.
接触网覆冰不仅影响接触线的弛度、支柱的容量,在一定程度上还影响着接触网绝缘子的闪络电压。
The room temperature vulcanized (RTV) silicone rubber coating on the surface of insulator can incrcase the flashover voltage of insulators due to the migration of hydrophobicity of RTV coating.
研究了环境温度、硅橡胶的分子量、交联程度和涂层厚度等因素对憎水迁移特性的影响并对憎水性迁移机理问题进行了讨论。
The factors which influenced the surface flashover and the way to rise the withstand voltage are also been analyzed.
对影响表面闪络发生因素,提高表面闪络电压阈值方法进行了分析。
Over-voltage protector can be greatly reduced near lightning flashover rates caused by induction voltage.
过电压保护器可以大大降低附近雷击感应电压导致的闪络率。
When bearing operating voltage, switching overvoltage or atmospheric over-voltage in the process of operating, the transmission line are likely to occur insulation flashover accident.
输电线路在运行过程中承受工作电压、操作过电压或大气过电压时,都可能会发生绝缘闪络事故。
The insulation characteristic of insulator in vacuum is researched in the process of the high voltage breakdown along the insulator surface in vacuum, which is called vacuum surface flashover.
绝缘子的真空表面绝缘特性研究真空下的高压沿绝缘子表面击穿物理过程,称真空表面闪络过程。
This thesis is based on the platform of the high voltage nanosecond pulse flashover in vacuum experiment and focused on the later digital signal processing to the sampled nanosecond signal.
本文以高压纳秒脉冲真空闪络实验平台为基础,侧重于对采集的纳秒脉冲信号作后期的数字信号处理。
Reflux of electron of high voltage vacuum diode is one of the main factors to cause the dielectric surface flashover.
真空高压二极管中的电子回流是造成绝缘子表面闪络的重要因素。
The composite insulator is light, and has low voltage of pollution flashover, so it's widely used in the power system in China.
复合绝缘子以其重量轻、防污闪性能好等优点在我国电力线路中已得到越来越广泛的应用。
In view of the huge damage of high voltage insulator contamination flashover, an on-line monitoring and measurement system of insulator contamination based on free software is designed.
针对高压绝缘子污秽闪络的巨大危害,采用自由软件设计了绝缘子污秽在线监测系统。
According to the analysis, the back flashover and the step voltage formed when the lightning strikes a tree are the main causes of the disaster.
分析认为,雷电击中大树产生的雷电反击和跨步电压是造成这起雷灾的主要原因。
According to the analysis, the back flashover and the step voltage formed when the lightning strikes a tree are the main causes of the disaster.
分析认为,雷电击中大树产生的雷电反击和跨步电压是造成这起雷灾的主要原因。
应用推荐