Petroleum products - Determination of aromatic hydrocarbon types in middle distillates - High performance liquid chromatography method with refractive index detection.
石油产品。中间馏分产品中芳香烃类的测定。用折射指数检测的高性能液相色谱法。
Liquid flow field in a tube with a combination of a stenosis and a bifurcation was measured using refractive index matching technique.
通过折射率匹配方法,应用激光多普勒测速仪测量了突缩与分叉复合管内的液体流场。
The binary monomer system, Benzel methacrylate(BzMA) Methyl methacrylate(MMA) layer gradient refractive index(GRIN) plates can be successfully fabricated by liquid gel diffusion copolymerization.
采用溶液凝胶扩散共聚法可以成功地合成二元体系的甲基丙烯酸苄酯甲基丙烯酸甲酯层状梯度折射率板。
We suggested to stable the output light intensity by using the bistable optical device and use this new device to measure the density of liquid by refractive index modulation sensor.
我们提出采用光学双稳装置来稳定光源输出功率,并将它用于折射率调制型光纤传感器测量液体浓度的实验中。
The experiment method of measuring refractive index of transparent liquid with spectrometer is improved.
介绍了利用三棱镜和分光计测量透明液体折射率的一种实验方法。
The method of measuring liquid refractive index with Michelson interferometer has been introduced.
本文介绍了用迈克逊干涉仪测量液体折射率的方法,原理简单。
The ways of measuring the liquid refractive index are discussed through the width of interfered stripe by using experimental set of wedge interference.
提出了用劈尖干涉实验装置,通过测量干涉条纹的宽度来测量液体折射率的方法。
A method of investigating how refractive index of transparent liquid varied with temperature by using Michelson Interferometer was proposed.
文章提出了一种利用迈克尔逊干涉仪研究透明液体折射率受温度影响变化的实验方法。
The sensor head of fusion fiber-optic single-point liquid-level sensor is investigated experimentally and theoretically in this paper, which is sensitive to the refractive index of surrounding media.
本论文从理论和实验上对周围介质折射率敏感的触点式熔接型光纤液位传感器的传感头进行了研究。
The instrumental error of the sensor was estimated through measuring to the refractive index matching liquid.
通过测量折射率匹配液,对传感器误差进行了估计。
The technique of leaky mode is applied to liquid crystal whose refractive index is smaller than that of the substrate.
在液晶折射率小于衬底折射率的条件下,利用漏模技术测量液晶的折射率以及液晶盒的厚度。
In this paper, the author describes the experimental installation and the principle of using diffraction grating to determine the refractive index of solid and liquid.
本文叙述了利用光栅衍射法来测定液体和固体折射率的实验装置及原理。
The result indicates that the error of the test for refractive index of polymer is less than 5%, while for volume percent of liquid crystal, the maximum error reaches about 10%.
结果表明,对聚合物分散液晶聚合物折射率的误差在5%以内,而对液晶体积分数的测试误差较大,达到10%左右。
Refractive index change created by laser induced thermal effect in liquid crystal been studied theoretically.
从理论上分析了在液晶中由于激光感生热效应所产生的折射率变化。
A new method for measuring the refractive index of liquid is proposed in this paper.
本文提出一种测量液体折射率的新方法。
The refractive index was obtained through measuring the focal position of a capillary filled with the liquid by a reading microscope, and doing a calculation with an analytic formula.
该方法基于共轴球面光学系统的成像原理,通过读数显微镜对吸入待测液体后毛细管的焦点位置进行单一参数的测量,进而计算出待测液体的折射率。
Abstract: In this paper, liquid refractive index was measured with Newton's rings and the application of Newton's rings experiment device was extendend.
摘 要:本文用牛顿环测液体折射率,对牛顿环实验装置的应用进行了扩展。
The expression of evanescent wave function is derivated, the phenomena of ATR! and the principle of measuring refractive index of liquid using SPR sensor are introduced.
推导了消失波函数的表达式,介绍了衰减全反射现象及SPR传感器测量液体折射率的原理,并利用SPR传感器测量了牛奶样品的反射系数及折射率与脂肪等主要成分含量的关系曲线。
The lyotropic liquid crystalline behavior of a natural macromolecule-chitosan was studied using polarized microscopy, average refractive index method and FTIR.
用偏光显微术、平均折射率法和富立叶红外光谱法研究了壳聚糖的溶致液晶行为。
The lyotropic liquid crystalline behavior of a natural macromolecule-chitosan was studied using polarized microscopy, average refractive index method and FTIR.
用偏光显微术、平均折射率法和富立叶红外光谱法研究了壳聚糖的溶致液晶行为。
应用推荐