常用硫酸钡比浊法和容量法来测定。
Barium sulfate turbidimetry and volumetric method are common methods.
方法采用比浊法,并与管碟法比较。
Methods Turbidimetric method was used to determine streptomycin sulfate, compared with diffusion method.
方法采用免疫透射比浊法进行检测。
测量聚集采用通常的比浊法。
Aggregation is determined by the usual turbidimetric method.
白蛋白测定采用免疫比浊法。
方法采用比浊法,并与管碟法相比较。
Method Turbidimetric method was used to determine kanamycin sulfate injection, compared with diffusion method.
结果比浊法、管碟法效价测定结果一致。
Results The result of turbidimetry was consistent with that of cylinder-plate method.
可得到目视比浊法不能得到的连续数据。
The results obtained by this method have no notable difference as compared with those obtained by the gravimetric method.
结果:比浊法、扩散法、高效液相法结果一致。
Result: The result of turbidimetry was consistent with that of diffusion and HPLC.
共振光散射比浊法;
目的对速率散射比浊法和乳胶凝集法进行比较。
ObjectiveNephelometric analysis and latex agglutination test were compared.
利用比浊法,以OP乳化剂作为稳定剂测定酸性镀铜液中的氯离子。
Cholride ions in acid copper plating bath were determined by nephelometry with op emulsifier as stabilizer.
目的:应用动态比浊法鲎试验定量测定生脉注射液中的细菌内毒素。
Objective: the kinetic turbidimetric Limulus test was used in the endotoxin assay of Ligustrazin Hydrochloride injection.
目的:应用动态比浊法鲎试验定量测定参麦注射液的细菌内毒素含量。
Objective: the kinetic turbidimetric limulus test was used in the endotoxin assay of Shen Mai injection.
目的应用动态比浊法鲎实验定量测定血液透析滤过液中的细菌内毒素含量。
Objective To determine bacterial endotoxin in the replacement solution of on-line hemodiafiltration (on-line HDF) using kinetic turbidimetric limulus test.
目的应用动态比浊法鲎试验定量测定注射用头孢他啶中的细菌内毒素含量。
AIM the kinetic turbidimetric Limulus test was used in the endotoxin assay of Ceftazidime injection.
方法分别采用微生物比浊法和管碟法对麦白霉素的含量进行测定和比较研究。
METHODS the diffusion method and turbidimetric method were used to determine the content of Meleumycin.
方法分别采用微生物比浊法和管蝶法对阿奇霉素的含量进行测定和比较研究。
METHODS the diffusion method and turbidimetric method were used to determine the content of azithromycin.
所有入选患者入院时立即给予冠状动脉造影术,CRP测定采用散射速率比浊法。
Coronary angiography was performed immediately after admission in all patients. CRP levels were measured by scatter rate turbidity comparison.
方法应用散射速率比浊法检测96例不稳定性心绞痛患者血浆C -反应蛋白水平。
Methods The level of plasma C-reaction protein of 96 cases unstable angina was detected with scattering rate turbidimetry method.
并以比浊法观察了O2诱导的人洗涤血小板的聚集及APNF(0134)对其的影响。
A turbidimetric method was used to measure human washed platelet aggregations induced by O2 and effects of APNF (0134) on them.
用比浊法和平板菌落计数法测定酿造酱油中菌数的变化,研究荸荠皮提取物在酱油中的抗菌效果。
The anti-microbial effect of extract of eleocharis tuberosa peel (EETP) in soy sauce was studied with the microbial changes in brewing soy sauce by turbidimetry and plate colony-counting methods.
叙述了在停电检修等异常情况时,用比浊法测氯乙烯的方法,并且对该方法的可行性进行了探讨。
The VCM content determination by turbidimetry on abnormal conditions (such as examination reparation in power cut and etc. ) was described. And the feasibility of this method was discussed.
方法采用比浊法和管碟法对硫酸庆大霉素颗粒的效价测定进行比较,并对比浊法进行方法学验证。
Methods Turbidimetric method was used to determine the titer of gentamycin sulfate granules and the findings were compared with those detected by diffusion method.
方法用速率散射比浊法检测71例急性有机磷农药中毒患者尿转铁蛋白,并与45例正常对照比较。
Methods Testing urinary transferrin with rate scatter nephelometry in 71 patients with acute organophosphorus pesticide poisoning, and compared with 45 cases of normal control.
方法对采用胶乳增强透射免疫比浊法直接测定RF失败的55例血清标本进行特殊处理,并重新测定。
Methods To make a special treatment and redetermination for the serum specimen of 55, the RF of which were directly detected with latex particle enhanced immunoturbidimetric assay unsuccessfully .
用四苯硼钠比浊法对该菌株的解钾能力进行测定,结果为实验组水溶性钾含量比对照组增加30.5%;
The ability of its dissolving potassium has been measured by the way of colorimetry. The potassium content of experiment group increased by 30.5%.
方法:同时用自动化散射比浊法、乳胶凝集试验和溶血抑制法检测12 0例临床患者的血清A SO。
Methods:The ASO of in serum of 120 patients were detected by immunonephelometric method, latex agglutination test and hemolytic inhibition assay at the same time.
包括:分光光度法、比浊法、原子吸收法、极谱法、电导法、离子选择电极法、离子色谱法和流动注射分析法等。
The methods are as follows: spectrophotometry, turbidimetry, atomic absorption spectrometry, polarography, conductance, ion selective electrode, ion chromatography, and flow injection analysis etc.
包括:分光光度法、比浊法、原子吸收法、极谱法、电导法、离子选择电极法、离子色谱法和流动注射分析法等。
The methods are as follows: spectrophotometry, turbidimetry, atomic absorption spectrometry, polarography, conductance, ion selective electrode, ion chromatography, and flow injection analysis etc.
应用推荐