均应报告标准偏差、相对标准偏差和可信限。
Standard deviation, RSD and confidential limit should be reported.
回收率在99%以上,相对标准偏差在2%之内。
The average recoveries were above 99% and the relative standard deviation within 2%.
方法的精密度优于区域采样法,相对标准偏差小于3%。
The precision of this method is better than the zone sampling method. The relative standard deviation (RSD) is less than 3 %.
有关物质含量测定结果稳定,相对标准偏差为2.33%。
检查中,你们不能提供支持你现行相对标准偏差标准的验证数据。
During our inspection, you were unable to provide validation data to support your current RSD criteria.
此法的重现性试验的相对标准偏差为1。73%,表明重现性较好。
The relative standard deviation of the reproducibility for this method is 1.73%, which indicated that reproducibility is good.
计算9个测定结果的回收率及相对标准偏差,均应在规定限度之内。
The recovery value and RSD of testing results shall be calculated and within specified ranges.
实测硅灰石中锰含量,相对标准偏差(R S D)为1.5% ;
Mn in wollastonite was determined actually , relative standard derivation(RSD) is 1.5% .
对两种复方消毒剂中氯己定含量进行重复测定,相对标准偏差为3.2%。
Repeated measurement of chlorhexidine content in 2 kinds of compound disinfectants showed that the relative standard deviation was 3.2%.
对医学文献提出的成本大约每年20000美元来治疗病人平均相对标准偏差。
Review of the medical literature suggests a cost of about $20,000 a year to treat an average patient with RSD.
平行测定结果的相对标准偏差为3 ~ 5%,加标回收率为95 ~ 102%。
The recovery of sulfur was 95 ~ 102% and relative standard deviation 3 ~ 5%.
将该方法用于镀镍电极的镍磷含量分析,测定结果的相对标准偏差不大于5.0%。
The method was effective in analysing the content of nickel and phosphor of the platinized nickel electrode, and the relative error range to the standard was not more than 5.0%.
实验表明试液的物理性质与空白溶液一致,测定结果的相对标准偏差小于2.1%。
The test indicated that the physical properties of test solution is identical with its blank solution. RSD were less than 2.1%.
本方法对阳性血清重复测定11次的结果显示,其相对标准偏差(RSD)为5.5%。
The relative standard deviation (RSD) was 5.5 % in 11 times measurement of standard positive serum.
考察分析方法的精密度和准确度,元素的测定结果与认定值一致,相对标准偏差小于2%。
The accuracy and precision of this method were studied. The results are consistent with the certified values and have relative standard deviation of less than 2%.
对氟苯甲酸加标回收率为99.9%,对氟聚苯乙烯分析结果的相对标准偏差为2.7%。
The recovery per cent of the standard addition ofp-Fluorobenzoic acid for this procedure equals 99.9%, the relative standard error is 2.72%.
线性方程的相关系数大于0.99,大部分药物回收率的相对标准偏差(RSD)小于10%。
The correlation coefficient of standard curves was larger than 0.99, and relative standard differences (RSD) were less than 10% for most of the drugs.
对于样品中的主要组分,测定的相对标准偏差可控制在1%以内,对微量组分可控制在10%以内。
The relative standard deviation of the measurements could be controlled to be less than 1 % for major components and less than 10% for minor components in the solid samples.
该方法的测定结果与原子吸收光谱法基本一致,标准偏差为0 04,相对标准偏差为1 45%。
The results consists of atomic absorption spectrometry. Standard deviation 0.04, relative standard deviation 1.45%.
自动进样器重复性的测试,一般取同一样品溶液至少重复进样10次,其相对标准偏差不应大于1%。
During automatic sampler repeatability test, a homogenous solution shall be at least sampled and injected for 10 times, and the RSD of results shall not be greater than 1%.
应用该法测定腐肥中的硼测定回收率为100%,标准偏差为2.04,相对标准偏差为2.04%。
Experiment results shows the rate of recovery is 100%, the standard deviation is 2.04, the relative standard deviation is 2.04%.
结果:加标回收试验结果表明,残留化学助剂加标回收率为89~95%,相对标准偏差均小于2%;
Result Standard addition test results suggests that the recoveries of chemical additive residues were 89%-95% with relative standard less than 2%.
结果表明,该方法重现性好,木二糖迁移时间和峰面积的相对标准偏差分别在0.5%和2.0%以内。
The result indicated that the relative standard deviations for xylobiose's migration time and peak area were all less than 0.5%, and 2.0% respectively.
经t检验证明,该方法的测定结果与微量凯氏定氮法无显著差异,测定结果的相对标准偏差为3.1%。
There is no significant difference between the result of the method and that of micro-Kjeldahl′s method according tot test. The relative standard deviation is 3.1%.
实验结果表明,五氯酚与吸光度成良好的线性关系,平均回收率96.3%,相对标准偏差3.16%。
The concentration of pentachlorophenol have favourable linearization with their absovbency. The average recycle efficienay is 96.3%, and the relalively standard windage is 3.16%.
采用高温催化-库仑滴定法测定植物叶片中的硫含量,相对标准偏差为1.5%,准确度为99.7%。
The sulfur content in Plant leaf is determined by high temperature catalysis-coulomb titration with the RSD is 1.5% and the accuracy is 99.7%.
研究了酸度、碘化钾浓度、还原剂用量对测定影响。测定的相对标准偏差为1.08%,方法简单、快速。
Effects of acidity, concn. of potassium iodide and dosage of reducing agent on determination are investigated. It is simple and rapid with relative standard deviation 1.08%.
结果表明,在此条件下测定的数据具有良好的精密度,相对标准偏差为1.52%,回收率在98%以上。
The results show that the data determined by this method have good precision, relative standard deviation is 1.52% and recovery is over 98%.
该方法用于聚氨酯中微量游离异氰酸酯基的测定,相对标准偏差小于5%,具有简便、快速、准确、可靠的特点。
The relative standard deviation (RSD) of this method is less than 5 % and this method has been used to determine trace amounts of n...
该方法用于聚氨酯中微量游离异氰酸酯基的测定,相对标准偏差小于5%,具有简便、快速、准确、可靠的特点。
The relative standard deviation (RSD) of this method is less than 5 % and this method has been used to determine trace amounts of n...