Can reliably determine, within the community and bounds detection ma level and zero-sequence current phase short circuit fault current, automatic removal of single-phase ground fault and phase fault.
能可靠判断、检测界内与界外毫安级零序电流及相间短路故障电流,实现自动切除单相接地故障和相间短路故障。
This method can test phase sequence of phase switcher while rectifying the zero point of phase switcher. This method is simple and value in practice.
该方法可以在对移相器零点校正同时进行移相器相序检验,方法简单,具有实用价值。
The properties and selection of the zero-phase sequence current transformer core and tripper for GFCI are in detail described.
详细叙述了漏电开关零序电流互感器及其铁芯,脱扣器的工作特性、材料选用。
Experimental results prove the proposed control method can compensate the harmonic, negative sequence and zero sequence current components in the three phase four wire.
实验结果表明,该装置可对三相四线制系统中的谐波、负序、零序等电流分量进行补偿。
It is derived that the phase of the FFT for a conjugate-symmetric sequence is zero.
推导出共轭对称序列的快速付里叶变换FFT具有相位为零的特性;
The phase comparison error is the primary factor leading to mistaken action in the selective leakage protective system of underground LV networks based on zero sequence current direction.
在基于零序电流方向原理的矿井低压电网选择性漏电保护中,比相误差是导致保护误动的主要因素。
In typical six-phase transmission system, half positive sequence, half zero sequence and half negative sequence fault components are independent of the variance of system impedance.
在典型的六相输电系统中,半正序、半零序和半负序故障分量不受系统阻抗变化的影响。
Zero-sequence current criterion, negative sequence current criterion and phase current variation can be used to improve the performance of breaker failure protection for ACF sub-bank.
针对单纯采用相电流判据的不足之处,本文提出增加零序电流、负序电流及电流变化量判据,以有效地避免保护误动或者拒动。
Use is made of that zero-sequence transformer outputs a voltage signal when phase-failure occurs in three-phase induction motor.
这种新方法的基础是零序变压器在三相异步电动机断相时输出一个电压信号。
At the time of failure, no matter what kind of start state of voltage phase, the zero-sequence transient current has the characteristic of inverse phase.
在故障时刻,无论故障相电压的相位处在何种初始状态下,都有零序电流反向的特征。
Zero-sequence transient energy is calculated for low earthing resistance and single-phase transient energy for high earthing resistance.
并且根据接地电阻的大小选择不同的暂态能量算式,故可判断金属性接地故障和高接地电阻接地故障。
By analyzing the zero-sequence full current for single-phase grounding fault in isolated neutral distribution network, a new approach to determine the faulty transmission line is obtained.
通过对中性点不接地配电网单相接地故障时零序全电流的分析,得出了利用零序全电流的大小和方向进行故障选线的新方法。
It is found that output voltage of zero-sequence transformer is proportional to voltage UA 'a between phase-failure points.
经研究发现,零序变压器输出电压与断相点间电压u _ (A' A)成正比。
In this paper, the instantaneous model of zero-sequence circulating current between parallel three-phase inverters with three-pole reactors and three-pole transformers is established.
该文基于三磁柱变压器及三磁柱电感的动态方程建立了带三磁柱电感及三磁柱变压器的三相逆变器瞬时零序分量模型。
The healthy line is unloaded for zero-sequence component when a single-phase fault occurs in a non-solid earthed network.
小电流接地系统发生单相接地故障时,对零序分量而言,非故障线路相当于空载。
So it is necessary to find some ways for the fault location detection. In the phase-to-earth fault power system, the value of zero-sequence impedance is directly related to the earth conductivity.
这样就降低了供电可靠性,故找出一种新思路使其能更准确有效地判断故障点具有重要意义。
So it is necessary to find some ways for the fault location detection. In the phase-to-earth fault power system, the value of zero-sequence impedance is directly related to the earth conductivity.
这样就降低了供电可靠性,故找出一种新思路使其能更准确有效地判断故障点具有重要意义。
应用推荐