文中所探讨的相电流突变量选相元件,是利用单相接地故障时,两健全相相间电流突变量为零这一特征来得到的。
The fault phase selector discussed is based on the result that the fault component of sound phases is zero when a single-phase-to-ground fault occurs.
结合自动补偿电网的特征,对利用零序电流的附加有功分量进行单相接地故障选线进行了研究与分析。
The paper made research and analysis on the topic of faulted line selecting in an auto compensated distribution network in use of the active part of residual currents.
该文提出利用线路故障产生的暂态行波实现配电架空线、电缆混合线路单相接地及相间短路故障测距,分析了故障初始行波模分量的暂态特征。
Using transient traveling waves generated by fault to locate single-phase earth fault or short circuit fault in distribution feeders mixed with overhead lines and cables is proposed.