摘要确认颅内电极置入的位置是否正确。
Objective: To confirm the location of the electrode contacts which were implanted into the cranium.
置入电极后,17例(58.6%)出现暂时性脑脊液外漏,3例出现颅内少量血肿,1例出现深部电极折断。无感染和死亡病例。
After the electrode placement, 17 patients (58.6%) had a temporary CSF leaking, 3 had less subdural hematoma, 1 had deep electrode disjunction, and no infection and death occurred.
结论植入电极描记清醒状态下小鼠颅内脑电图更稳定、可靠,可作为研究药物等其他处理因素时描记脑电图的模型。
Conclusion Intracranial EEG recording on freely moving mice with implanted electrode is stable and reliable for further study on drug development.
结论植入电极描记清醒状态下小鼠颅内脑电图更稳定、可靠,可作为研究药物等其他处理因素时描记脑电图的模型。
Conclusion Intracranial EEG recording on freely moving mice with implanted electrode is stable and reliable for further study on drug development.