利用静电探针可以对等离子体的基本参数如:电子温度和电子密度进行测量诊断。
The plasma parameter, such as electron temperature and electron density, can be diagnosed by the static electricity probe.
用混沌动力学方法对多道扫描静电探针的离子饱和电流信号进行分析,研究了等离子体尾迹流场。
A plasma wake flow field is studied by analyzing the saturated ionic current of multiple scanning probes with the method of chaos dynamics.
本文建立了一套静电探针诊断系统,在国内首次对以氩气为推进剂的电弧加热发动机羽流电子温度进行了测量。
A Langmuir probe diagnostic system for Arcjet plume is established first in China, in which Langmuir probe is employed to obtain the electron temperature of the Arcjet plume with argon propellant.
计算获得的偏滤器内外靶板上打击点出现和消失的时间与布置在偏滤器靶板上静电探针测量到的信号很好地符合。
The time of the appearance and disappearance of the strike point at the target is in agreement with the signals measured by the static electric probes.
本文描述了用静电探针测量探针悬浮电位的方法,给出MM-4中电位分布的实验结果。结果表明轴向电位分布不对称,径向分布对称;
Some experimental results of the potential distribution in MM-4 fusion device are presented by measuring the floating potential of probe.
实验结果表明,赖氨酸分子在电极表面组装形成的单层膜不很致密,对于呈负电性的活性探针离子具有静电排斥作用。
The experiment results indicated that there is a not very compact Lysine monolayer on the surface of glassy carbon electrode, which has an electrostatic repulsion to the negative REDOX probe.
利用朗缪尔静电双探针诊断了蒸发镀膜装置反应室内等离子体密度及分析其分布规律,并分析了气压和功率对等离子体分布的影响。
The characteristic of spatial distribution of plasma ion density in reaction chamber were diagnosed by a Langmuir double probe, and the effect of Ar pressure and RF power were also investigated.
三种氨基酸修饰玻碳电极表面在中性溶液均呈现荷负电性,对于带负电荷的活性探针离子均具有静电排斥作用。
In neutral condition, three kinds of amino monolayer show electronegative, which has an electrostatic repulsion to the negative REDOX probe.
用静电悬浮双探针测量了电子温度和离子温度。
The electron temperature and ion density were measured by a floating double-probe.
用静电悬浮双探针测量了电子温度和离子温度。
The electron temperature and ion density were measured by a floating double-probe.