External flow switch inhibits pump output when no sample flow is available.
在没有可用的样本时,外部流量开关将会抑制泵输出流量。
Single cover retaining screw mounted on top of the flow switch for easy access.
在流量开关上安装一个盖子固定螺丝,便以打开进入。
Flow switch can be installed in a reducing tee, standard tee or welded fitting.
开关可以安装在异径三通管,标准三通管或焊接管件上。
Start the bilge water feed pump, check the feed water solenoid valve and flow switch.
启动舱底水供给泵,检查补水电磁阀和流量开关是否工作。
Flow switch damage should be promptly repair or replace, must not short sub flow switch.
流量开关损坏时要及时进行修理或更换,切不可短接流量开关。
Mount flow switch in position so that the paddle assembly is at a right Angle to the flow.
安装流量开关定位要正确,要使得开关叶片总成与水流形成直角。
If a Flow Switch, Float Switch, or other type of sensor is used, please contact Watts for compatibility.
如果采用流量开关、浮动开关,或其他类型的感应器,请咨询美国瓦茨,了解兼容性。
Flow switch used to sound alarm, light signal, actuate relays or starter switches for motors, pumps, etc., when no flow occurs.
流量开关用于声音报警,灯光报警,当无流量时启动电机、泵等继电器或起动器开关。
In order to prevent water or recycling water within the system from freezing, the unit is installed with rake-type flow switch;
为防止缺水或循环水系统内部结冰,机组安装了耙式流量开关;
The F61 serial liquid flow switch is widely used for conditioning, freezing and other places which need "setting off" protection.
这款液体流量开关广泛应用于空调、冷冻等需要断水保护的场合。
Use the Weld Shield Gas Flow Switch to give your PLC or control system a signal that allows for simple detection of flow problems.
使用焊接保护气体流量开关,让您的PLC或控制系统的信号流问题的简单检测允许。
Parts in contact with liquid in pipe are of brass and beryllium copper. Flow switch installs in tee in horizontal or vertical piping.
在管道内与流体接触的部件是黄铜和铍铜合金。流量开关以三通管方式安装在水平或垂直管道上。
Pre-wired and tested controls which include control circuit, high and low pressure safety switches, 24 volt control circuit, flow switch & ETL Listed.
预有线和测试控制,包括控制电路,高低压安全开关,24伏的控制电路,流量开关。
Reed switch; Proximity sensor; Float Sensor; E-bike Brake Switch; Reed Relay; Flow Switch; Tilt Sensor Switch; Vibration Sensor Switch; Centrifugal Force Sensor Switch.
干簧管;接近开关;浮球开关;电动车刹车开关; 干簧继电器;水流开关; 角度开关;震动开关;离心力开关。
Based on a water-break protection requirement of water-cooled air compressor, describes the principle, selection and the advantages of the target flow switch are described.
依据水冷式空压机需要断水保护的要求,介绍了靶式流量开关的工作原理、选用方法以及在断水保护中的优势。
Lake's weld Shield Gas Flow Switch has been developed specifically for use in harsh welding applications and will hold up to the typical conditions of the welding environment.
湖的焊接保护气体流量开关是专为在恶劣的焊接应用,并可以保存,焊接环境的典型条件。
The KL61/PFS-F25 series flow switch has been specifically developed to fill the need for a flow sensor, capable of working reliably in applications in which metal flow switches fail.
在KL61/PFS-F25系列流量开关已专门开发填补了流量传感器的需要,工作在应用中,金属流量开关不能可靠的能力。
Common form of the pressure switch, volume switch, time switch and flow switch, that is, to achieve the preset inspiratory pressure, capacity, time or flow rate is converted to breath.
常见的方式有压力切换、容量切换、时间切换和流速切换,即吸气达到预置的压力、容量、时间或流速则转为呼气。
F61 serial liquid flow switch suits for measuring the liquid flow conditions from the pipes, such as: water, ethylene, glycol or other liquid which will not corrupt brass or phosphor bronze.
F61系列的液体流量开关,用于测量流经管道的液体流动状态,例如:水、乙烯、乙二醇或任何对黄铜、磷青铜无腐蚀作用的流体。
The main products are Freezer, Cooler, Heat-up Machine, Air-Compressor, Air-conditioning Epuipment and other Various complete series of Pressure Controls, Pressure Differential Controls, Flow Switch.
主要产品是与冷冻机,冷却机,加热机,空气压缩机及空调器配套的各种不同系列的压力控制器,压差控制器,流量开关。
In the previous picture, you can recognize some logical constructs that help with structuring the flow with conditional execution (the Switch activity) and with cycles (the Loop).
在前面的图中,您可以辨认出一些逻辑结构,这些结构可以使用有条件执行(Switch活动)和周期(Loop)帮助构建此流。
The key here is that the Pending changes view allow you to switch between any the streams or workspace to or from which you need to flow changes.
这里的关键之处在于,Pending Changes视图允许您在任意的流或者工作区之间切换,您可以从中进行流变更。
Handlers generally save the current state of the flow and execution and will switch to a predefined handler flow.
处理程序通常保存流和执行的当前状态,然后切换到一个预定义处理程序流。
Deploy the 10 gigabit Ethernet switch that supports priority-based flow control and loss-less Ethernet similar to a typical switch deployment.
部署10千兆以太网交换机,支持基于优先级的流量控制和类似于典型交换机部署的无损耗以太网。
Connect to the switch using the serial console port with a straight serial cable (9600, 8-n-1, no flow control) with default no user ID or password required.
用串口直连电缆连接到每台交换机的串行控制端口(9600、8 -N - 1、无流控制),默认下不需要用户ID和密码。
Connect to the switch using the serial console port with a straight serial cable (9600, 8-n-1, no flow control).
用串口直连电缆连接到交换机串行控制端口(9600、8 - N - 1、无流控制)。
The palette contains a rich set of options for creating XForms controls, ranging from flow constructs such as switch and repeat, to simple controls such as an XForms input or text area.
选项板包括丰富的XForms控件创建选项,从分支和重复这样的流控制,到 XForms输入和文本区域这样的简单控件。
First, connect to each switch using the serial console port with a straight serial cable (9600, 8-n-1, no flow control) with a default user ID admin and no password.
首先,用串口直连电缆连接到每台交换机的串行控制端口(9600、8 -n - 1、无流控制),使用默认用户IDadmin,无密码。
Flow indicator light integral with switch cover. Indicates flow or no flow conditions.
与开关盖一起配置的流量指示灯。指示有流量或无流量情况。
Logic statements like WHILE and SWITCH that allow flexible business processes that can change process flow based on the specific case.
像WHILE和SWITCH这样的逻辑语句,提供了灵活的业务流程,可以根据特定的情况改变流程。
应用推荐