• Forced air cooling, Signal cylinder, 4-stroke.

    单缸,四冲程,强制风冷发动机。

    youdao

  • When forced air cooling can over 40% rated capacity.

    在强迫风冷时可使额定容量超40%左右。

    youdao

  • The forced air cooling device for 600MW unit after shutdown is introduced.

    介绍了600MW机组停机后的空气强制冷却装置,并对其使用中的操作步骤;

    youdao

  • Forced air cooling is a reasonable shut-down cooling mode of steam turbine.

    汽轮机停机后用压缩空气强迫冷却是合理的冷却方式。

    youdao

  • Local put low power, the noise is small, cooling function of strong, forced air cooling conditions can be 150% rated load operation.

    局部放电量低,噪音小,散热功能强、强迫风冷条件下可以150%额定负载运行。

    youdao

  • This series applies originally imported compressor. The forced air cooling presents speedy cooling and uniform temperature inside a cabinet.

    采用原装进口压缩机,强制风冷,冷却速度快,柜内温度均匀。

    youdao

  • The reasons of producing electric particle of gas and the condition of air flowing in large current enclosed busbar with forced air cooling are analysed.

    分析了强迫风冷大电流封闭母线中气体带电粒子产生的原因和其中的气体流动状况;

    youdao

  • The forced air cooling is an important component of motorcycle, playing a key role in radiating heat, cooling and as well as keeping the normal temperature of engine.

    强制风冷系统是坐式摩托车的重要组成部分,它起着散热冷却、保证发动机温度正常的作用。

    youdao

  • With a example design of a transmitter, the design and computation process of the method is discussed in detail, and reasonable design result of forced air cooling is presented.

    并以某发射机的强迫风冷散热设计为例,详细阐述了此方法的设计计算过程,给出了强迫风冷系统合理的设计结果。

    youdao

  • The forced air cooling device for 600mw unit after shutdown is introduced. The operation procedures, noteworthy points, effect after the device putting into service are described in detail.

    介绍了600MW机组停机后的空气强制冷却装置,并对其使用中的操作步骤;注意事项;投入使用后的效果进行了详细的阐述。

    youdao

  • Aiming at the thermal design problem of high-power components in electronic equipments, this paper introduces one practical thermal design method of forced air cooling of electronic equipment.

    针对电子设备中高功率器件的热设计问题,介绍了一种实用的强迫风冷散热设计方法。

    youdao

  • In forced-air heating and cooling systems, ducts carry hot or cold air to different parts of home.

    在强制热风和冷风系统中,通风管道将热空气的冷空气输送到家里不同的地方。

    youdao

  • With the advantages of convenience of design, ease of application and low cost, forced air-cooling with heat sinks and fans are now the most widely used cooling technology for electronic devices.

    散热器和风扇组合的强迫风冷技术具有设计简单、使用方便、成本低廉等优势,是目前电子设备中应用最广泛的冷却技术。

    youdao

  • Under this background, the present study of the heat transfer and flow characteristics of plate fin heat sinks and staggered heat sinks with forced air -cooling were carried out.

    本文关于强迫风冷中板翅式和叉排式散热器换热性能和流动特性的研究即以这一重要领域为背景。

    youdao

  • The heat exchanging construction is used to carry out forced air-cooling on the external surface of the HEJ to re-duce its working temperature.

    采用换热结构在炉胆外侧作强制空气冷却,以降低炉服的工作温度;

    youdao

  • Compared to the condition of air cooling, forced cooling significantly improves the mechanical properties of FSW joint.

    与空气条件下相比,强制水冷条件明显改善接头的力学性能。

    youdao

  • By contrast of the new forced-air cooler in transformers to the old one, the design and effect of improvement of the old forced-air cooling system are discussed.

    通过变压器新旧风冷却器性能的对比,对老式风冷却系统改造的设计方案、改造效果进行了探讨。

    youdao

  • Countered problems in the forced-air cooling system of power transformer, the energy-saving device composed by converter is designed.

    针对电力变压器风冷系统存在的问题,设计了由变频器构成的节能装置。

    youdao

  • It can ensure the reliability of constant power charge that adopted uniformly stepped power input, energy consumption work model and forced air-cooling model.

    统一分段式功率投入,能耗式工作模式,强制风冷式散热,大大保证了恒功率放电的可靠性;

    youdao

  • Low ripple factor: it's of low interference to other equipments, forced air-cooling, automatically Shared load, low failure rate and high reliability.

    纹波系数低,对其它设备干扰小;强制风冷式散热,负荷自动均分,故障率低,可靠性高。

    youdao

  • For thermal management, ANSYS Icepak software provides system-level CFD simulation including conduction, radiation, and natural and forced-air cooling.

    对于热管理,ANSYSIcepak软件提供了系统级CFD的模拟,包括传导、辐射、以及自然和强制风冷。

    youdao

  • The research of the deep hole processing system which used gun-drill and the forced-air cooling technique;

    通过对深孔加工常用方法的分析 ,设计了一种集镗削、滚压于一体的组合镗滚刀具。

    youdao

  • The research of the deep hole processing system which used gun-drill and the forced-air cooling technique;

    通过对深孔加工常用方法的分析 ,设计了一种集镗削、滚压于一体的组合镗滚刀具。

    youdao

$firstVoiceSent
- 来自原声例句
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定
小调查
请问您想要如何调整此模块?

感谢您的反馈,我们会尽快进行适当修改!
进来说说原因吧 确定