Measurement of the grounding resistance is an important tache in grounding construction.
接地电阻测量是接地施工中的一个重要环节。
The usage and effect of grounding resistance reducing agent at low temperature is discussed.
讨论了低温条件下降阻剂的使用方法和降阻效果。
Tower grounding resistance, distance between towers, etc can affect the function of line-surge arrester.
输电线路的接地电阻,线路档距等因素对线路型避雷器的应用有影响。
Resistance-reducing agent does not reduce the impulse grounding resistance under large lightning current.
降阻剂并不能降低接地极在强雷电流下的冲击接地电阻。
Fourteen, system of pipe nozzle and stents are connected to ground, grounding resistance should be less than 16 ohms.
系统中的管道喷头及支架等均应接地,接地电阻应小于16欧姆。
A new analytic method for grounding resistance of compound grounding grids in two-layer soil is deduced in this paper.
提出计算双层土壤复合接地网接地电阻的新解析方法。
The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically.
采用数值计算方法分析了垂直接地极对接地系统的接地电阻、接触电压及跨步电压等的影响。
The location and quantity of arrestor and impulse grounding resistance of towers has direct influence on lighting overvoltage.
变电站避雷器安装位置和数量及输电线终端塔的接地电阻对雷电过电压有著直接的影响。
To meet the requirement of reducing unnecessary losses, we should reduce the grounding resistance of grounding grid as far as possible.
为达到要求减少不必要的损失,应尽量减小接地网的接地电阻。
Calculation results in CDEGS Software as a reference, discusses the complexity of soil effects on grounding resistance characteristics.
以CDEGS软件计算结果作为参考依据,探讨了土壤复杂化对接地电阻值的影响特性。
The measurement of grounding resistance under impulse voltage is of great importance for safe operation of power system and electronic equipment.
电力系统冲击接地电阻的测量是关系到电力系统稳定运行和电气设备安全的重要问题。
Finally grounding resistance and soil resistivity are measured under the condition of two-layer horizontal soil, and the model is proved to be reasonable.
实验测量了两层水平分层土壤结构下的接地电阻和土壤电阻率,证实了土壤分层模型的有效性和可靠性。
In this paper, the significance and area of low voltage grounding protection are described and some methods for measuring grounding resistance are introduced.
简述了低压用电设备保护接地的意义,保护接地范围,以及测量接地电阻的方法。
The analytic computational formula for grounding resistance of grounding rods in three-layer soil is derived based on the concept of equivalent soil resistivity.
基于等值土壤电阻率的概念,导出了三层土壤中垂直棒接地电阻解析计算公式。
It is pointed out that in modern lightningproof and grounding systems, it is the structure of the equipotential system not the grounding resistance that matters.
强调了在现代防雷接地系统中,重要的是等电位系统的结构而不是接地电阻阻值的大小。
Computation of spark discharge radius, impulse grounding potential distribution, current waveform and impulse grounding resistance is conducted by using this model.
应用该模型进行了火花半径、接地体冲击地电位分布、电流波形及冲击接地电阻的计算。
The paper introduces the characteristics of resistivity of several typical soils and grounding resistance reducing agents at low temperature based on laboratory tests.
介绍了在低温条件下对几种典型土壤以及各类降阻剂的电阻率特性进行实验研究的结果。
The seasonal coefficient of grounding resistance possibly reaches 3.0 in freezing region of North China, and those of touch voltage and step voltage 10 and 5.4, respectively.
在我国北方高寒冰冻地区接地系统的接地电阻季节系数可达3.0,接触电压和跨步电压季节系数可能达到10和5.4。
With a view to the deficiency of grounding resistance measurement at present, a new method with short current-electrode wire based on computer auxiliary analysis is presented.
针对目前的接地电阻测量方法的缺点,提出了以计算机辅助分析为基础的短电流极引线测量方法,并对电流引线长度的选取作了分析。
This fl at region would be misidentified as the compensation point of potential electrode corresponding to the actual grounding resistance of substation, and bring huge error.
该平坦段可能会被误认为对应于真实接地电阻的补偿点位置,导致测量结果出现巨大误差。
According to the practical situations of substation engineering, this paper analyzes the method to reduce grounding resistance. It helps for construction of substation earthing grid.
从变电站工程施工的实际情况出发,分析了变电站降低接地电阻的方法,以期对变电站接地网建设有所裨益。
The seasonal factor affects the safety of grounding system, and causes changes in the grounding resistance, the step and touch voltages on the ground surface above the grounding system.
季节因素将影响地网的安全性能,导致地网的接地电阻、接触电压和跨步电压的改变。
This paper introduces the principle of frequency changing method of grounding resistance measurement, the structure of frequency conversion measurement apparatus and data process method.
介绍了变频法测量接地电阻的原理、接地电阻变频测量仪的结构、数据处理方法和实测结果。
This paper describes and analyses in detail the testing results of long effective solid agent of decreasing grounding resistance of current with industrial frequency and impulse current.
本文详细介绍了长效固体降阻剂的工频和冲击试验结果并对此进行了深入的分析讨论。
The insulation methods of several DC systems are compared and analysed. A ping-pang variable bridge measurement is adopted. The ex - act on line detection of grounding resistance is realized.
比较分析了几种直流系统常用的绝缘检测方法,采用乒乓式变电桥测量法,实现了接地电阻的准确在线测量。
The simulation results shows that it decreases the negative influence made by wave velocity, line length and faults grounding resistance factors, and also improves the accuracy of faults locations.
仿真结果表明此算法减小了传统方法受波速、线路长度、故障接地电阻因素的影响,提高了故障测距的精度。
The lightning protection could be improved by means of decreasing grounding resistance of tower, installing line type surge arrester and side lightning rod as well as increasing the insulation level.
采取杆塔降阻、装设线路避雷器、侧向避雷针和加强绝缘等多种措施后,防雷保护效果较好。
Grounding resistance is not more than 30 ohms.
接地电阻不大于30欧姆。
Grounding resistance can be considered as the criterion of anchor quality.
本文采用接地电阻作为评价钢筋锚杆锚固质量的标准。
Grounding resistance is an important technical parameter of grounding system of electric power plant and transformer substation.
接地电阻值是发电厂、变电站接地系统的重要技术指标。