Protection devices is equipped with zero-sequence differential protection for the auto-transformer.
而保护装置针对自耦变压器,还配置了零序差动保护。
The inverse time delay characteristic is adopted by the basic zero-sequence over-voltage protection.
其基本保护采用零序过电压保护,动作时间采用反时限特性;
Also interference with telephone circuit is reduced because of the absence of zero-sequence currents.
由于无零序电流,对电话线路干扰的影响也降低。
A zero-sequence differential protection for transformer is discussed in scheme design and protective logic.
从保护方案设计和保护逻辑两方面详细论述了一种新型的变压器零序差动保护方案。
The zero-sequence differential protection ought to be added at the star winding of extra-high voltage transformer.
接线绕组的超高压变压器应增设零序差动保护。
The healthy line is unloaded for zero-sequence component when a single-phase fault occurs in a non-solid earthed network.
小电流接地系统发生单相接地故障时,对零序分量而言,非故障线路相当于空载。
It is found that output voltage of zero-sequence transformer is proportional to voltage UA 'a between phase-failure points.
经研究发现,零序变压器输出电压与断相点间电压u _ (A' A)成正比。
The zero-sequence measurement current's distribution in the automatic arc-suppressing coil earthed power system is analyzed.
分析自动跟踪补偿消弧线圈接地电网的零序测量电流分布规律。
In the meanwhile it is pointed out that the quantity change of the parallel line and zero-sequence impedance must be retested.
同时还指出平行线路条数变化,零序阻抗均需重新测试。
The validity check of zero-sequence operating direction for transformer directional over-current protection is also essential.
另外还需要进行变压器零序方向过电流保护动作方向正确性的检查。
A novel principle of negative-sequence current compensation based adaptive zero-sequence over-voltage protection is therefore proposed.
该文提出一种新的基于负序电流补偿的自适应零序过电压保护原理。
Three examples show that it's impossible to solve zero-sequence parameters just using transient measurement data in one operation mode.
三个算例表明:仅用一种运行方式下的暂态数据不能求解出零序参数。
Reasonable modification to zero-sequence voltage circuit and proper operation can minimize losses caused by faults of this kind, if it happens again.
合理地变更PT零序电压回路接线和正确的操作,对再发生此类事故可减小事故损失。
The method is independent of zero-sequence current's value, inductance compensation situation and harmonics components, so it is effective and robust.
该方法不受零序电流大小、线路补偿情况、谐波强弱等影响,具有较高的理论和实用价值。
This paper also proposed a new fault locating method based on either the active component increment or the amplitude increment of zero-sequence current.
提出了零序电流有功增量和零序电流幅值增量作为判据的故障点定位方法。
It is necessary to install zero-sequence differential protection because conventional differential protection is not sensitive enough to grounded fault.
通过分析变压器传统纵差保护在反映接地故障时灵敏度上的不足,论述了装设零序差动保护的必要性。
At the time of failure, no matter what kind of start state of voltage phase, the zero-sequence transient current has the characteristic of inverse phase.
在故障时刻,无论故障相电压的相位处在何种初始状态下,都有零序电流反向的特征。
How to check the connection correctness of "l", "n", "s" lines is discussed on the shortcomings of on-load test for zero-sequence power direction component.
针对当前零序功率方向元件带负荷试验的不足之处,讨论了如何检查“L”、“N”及“S”线的接线正确性。
In this paper, the instantaneous model of zero-sequence circulating current between parallel three-phase inverters with three-pole reactors and three-pole transformers is established.
该文基于三磁柱变压器及三磁柱电感的动态方程建立了带三磁柱电感及三磁柱变压器的三相逆变器瞬时零序分量模型。
By analyzing the zero-sequence full current for single-phase grounding fault in isolated neutral distribution network, a new approach to determine the faulty transmission line is obtained.
通过对中性点不接地配电网单相接地故障时零序全电流的分析,得出了利用零序全电流的大小和方向进行故障选线的新方法。
The zero-sequence parameter of transmission lines especially of transmission lines with mutual inductances is of great important in the relay protection setting calculation of power system.
输电线路的零序参数尤其是多回互感线路的零序参数是电力系统继电保护整定计算需要的重要参数,所以其准确测量具有重要意义。
The paper proposes a method which corrects the Angle of zero-sequence current in the algorithm of differential equation used for distance protection and fault location of HV transmission lines.
本文针对高压输电线距离保护及故障测距中常用的解微分方程算法,提出了一种零序电流相位修正的方法。
The new method turned the volt-ampere characteristic equation of transmission lines into an integral form, then used least square method to solve the equations and got the zero-sequence parameters.
该方法是将互感线路的伏安特性方程转化为积分形式,并采用了最小二乘法求解方程组,同时得出各线路的零序自阻抗及线路间的零序互阻抗。
Can reliably determine, within the community and bounds detection ma level and zero-sequence current phase short circuit fault current, automatic removal of single-phase ground fault and phase fault.
能可靠判断、检测界内与界外毫安级零序电流及相间短路故障电流,实现自动切除单相接地故障和相间短路故障。
Zero-sequence transient energy is calculated for low earthing resistance and single-phase transient energy for high earthing resistance.
并且根据接地电阻的大小选择不同的暂态能量算式,故可判断金属性接地故障和高接地电阻接地故障。
Zero-sequence current criterion, negative sequence current criterion and phase current variation can be used to improve the performance of breaker failure protection for ACF sub-bank.
针对单纯采用相电流判据的不足之处,本文提出增加零序电流、负序电流及电流变化量判据,以有效地避免保护误动或者拒动。
Main functions and characteristic for zero sequence current protection setting program are presented in this paper. Ways of no_balance zero sequence current for double lines are introduced.
主要介绍了零序电流保护整定计算程序的主要功能和特点,简要介绍了双回线零序电流的不平衡解决方法。
The zero sequence directional relay is an important relay component for transmission line.
零序功率方向继电器是线路保护中的一个重要元件。
It mainly focuses on analysis and determining method of zero sequence power direction relay.
重点介绍零序功率方向继电器的分析及判定方法。
A double lines distance relay based on the zero sequence components is presented.
提出了适用于平行双回线路的零序距离继电器新判据。
应用推荐